Registry Error Fix ModemHelp.Net Recommends: Free System Scan for PC Errors

Rockwell based 14400 bps Modem(DPi chipset) String Explaination


Rockwell based 14400 bps Modem(DPi chipset)

AT&FN1W2S7=55


AT: (beginning of most inits) Attention!

&F: Sets the values loaded in the active profile to the values that are set in the default profile.

N1: Turn on automode detection.

W2: (Extended result codes) sets modem to report CONNECT to DCE rather than DTE.

S7=55: Wait at least 55 seconds for carrier before discontinuing connection attempt.









This page was last modified on Wednesday, 18-Jul-2007 13:45:27 EDT.




 
This website is ©1999-2008 Bradford Liedel DBA ModemHelp Networks and Web Services. Mason, MI 48854 USA. All rights reserved.