Rockwell based 14.4 RPI String Explaination


Rockwell based 14.4 RPI

AT&FW2&C1&D2&Q6&K3S7=60


AT: (beginning of most inits) Attention!

&F: Sets the values loaded in the active profile to the values that are set in the default profile.

W2: (Extended result codes) sets modem to report CONNECT to DCE rather than DTE.

&C1: DCD enabled after a carrier signal is detected

&D2: DTR drop causes modem to hang up

&Q6: Buffered asynchronous mode

&K3: Enable RTS/CTS flow control

S7=60: Wait at least 60 seconds for carrier before discontinuing connection attempt.